Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com Thu, 14 Mar 2024 06:52:24 +0000 en-US hourly 1 //wordpress.org/?v=6.6.2 //gd-1.com/wp-content/uploads/2021/02/favicon-32x32.png Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com 32 32 Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/anatel-pat700-toc-analyzer/ Thu, 11 May 2023 06:39:19 +0000 //gd-1.com/?post_type=product&p=8027
  • TOC, Uncompensated Conductivity and Temperature from just one analyzer 鈥?can be fully calibrated and validated to聽USP 643聽and聽USP 645
  • Low cost of ownership 鈥?12 month service and calibration intervals
  • Root-cause analysis support 鈥?water sample automatically taken if there is a TOC excursion
  • All SOPs are pre-loaded into the PAT700, leading users step-by step with on-screen pictures and prompts
  • ]]>

    Low cost of ownership

    • 12 month service intervals supported by auto-switching Main and Standby UV oxidation lamps with UV output monitoring
    • No chemicals/reagents required 鈥?PAT700 just uses strong UV lamps to oxidize TOC
    • No peristaltic pump tubing or pump heads to replace 鈥?PAT700 uses water system pressure to push sample into measurement cell for analysis

    Root-cause analysis support

    • User can pre-program the PAT700 so that at a pre-determined TOC level, it will capture a water sample which can then be later analyzed in the QC Lab to assist root cause analysis should a TOC excursion be detected
    • On-board grab sampler allows the user to take samples from different locations/use points to support root cause analysis

    Improved compliance

    • PAT700 can be fully calibrated and validated for compliance to聽USP 643 for TOC and聽USP 645聽for conductivity
    • Complete oxidation to聽EP 2.2.44聽requirements 鈥?the PAT700 ensures complete TOC oxidation through oxidation dynamic end-point detection
    • 21CFR part 11 support聽鈥?everyday users can view TOC and Conductivity results as a Guest without the ability to make any changes to the PAT700. Initial configuration and subsequent changes are protected through multi-level user name and password protection
    • Dual-stream version available to demonstrate compliance both at the start and end of water loops simultaneously

    Reduced training burden 鈥?no manual calculations/data entry

    • All SOPs are pre-loaded into the PAT700, leading users step-by step with on-screen pictures and prompts
    • All Calibration and System Suitability standards come with certified value data and use by dates programmed into an RFID tag on the bottle itself. Following the on-screen SOPs the user is prompted to load the bottles and the PAT700 then reads the RFID tags on the bottles. If the bottles have been loaded in the wrong order, or if they have expired the PAT700 provides a warning on the touch-screen. The PAT700 then uploads certified values, carries out the test and automatically calculates a pass/fail result and provides a report.
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/prima-bt-bench-top-process-mass-spectrometer/ Tue, 03 Jan 2023 08:19:18 +0000 //gd-1.com/?post_type=product&p=7106 The Prima BT mass spectrometer is an industrial laboratory gas analyzer based on scanning magnetic mass spectrometry. Designed for continuous operation in process environments, the Prima BT mass spectrometer is simple to operate and easy to maintain.
    Features:
    • Magnetic scanning technology
    • 16-port fast multi-stream sampler (RMS)
    • 6-port automatic calibration manifold
    • High analytical accuracy and stability
    • Thermo Scientific鈩? class= GasWorks software
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/prima-pro-process-mass-spectrometer/ Tue, 03 Jan 2023 08:09:18 +0000 //gd-1.com/?post_type=product&p=7100
    • Significantly enhanced analyzer control, resulting in increased sensitivity, accuracy, precision and mass range
    • Completely redesigned electronics, incorporating higher specification components
    • Fast online process gas analysis (1 to 20 seconds per point) for precise monitoring of process dynamics
    • Comprehensive measurement with more data powered for advanced process control (APC) models
    • Stable with automatic calibration interval from 30 to 90 days
    • Reliable, fault-tolerant design for 99.7% higher availability
    • Complete service access from the front of the system, effectively reducing the footprint
    • Small footprints don’t need a big fulcrum
    • Requires minimal maintenance
    • Enhanced connectivity with DCS systems and offline data manipulation packages
    • Thermo Scientific鈩? class= GasWorks software
    Application:
    • fermentation
    • cell culture process
    • Iron and steel smelting process
    • Plant ethylene, ammonia, hydrogen
    • Ethylene oxide, methanol, polyethylene/polypropylene
    • Ethylene oxide process
    • catalyst research
    • solvent drying
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/sentinel-pro-environmental-mass-spectrometer/ Tue, 03 Jan 2023 07:50:45 +0000 //gd-1.com/?post_type=product&p=7094 The fast, accurate and reliable Sentinel PRO environmental mass spectrometer can monitor 100 or more sample points within 15 minutes. It features detection of several species-specific volatile organic compounds (VOCs) in the 1ppm 鈥?100ppm range. Rugged fault-tolerant design ensures availability in excess of 99.7%, and simplified maintenance procedures make it easy to own. A single Sentinel PRO analyzer can replace an entire rack of discrete, less sensitive analyzers to improve detection and significantly reduce ongoing maintenance and operating costs.
    Increased sensitivity, accuracy, precision and mass range:
    • Completely redesigned electronics, incorporating higher specification components
    • Capable of monitoring 100 or more sample points within 15 minutes
    • Species-specific VOC detection in the 1ppm 鈥?100ppm . range
    • Reliable, fault-tolerant design for 99.7% higher availability
    • Significantly enhanced analyzer control
    • Enhanced connectivity with DCS systems and offline data manipulation packages

    Features:

    • Provides a large number of sampling points that can be located near potential leak points (i.e. valve body, etc.)
    • Unique fast multi-threaded sampler (RMS) with 32 or 64 ports
    • Stable with automatic calibration interval from 30 to 90 days
    • Complete service access from the front of the system, effectively reducing the footprint
    • Small footprints don’t need a big shelter
    • Requires minimal maintenance
    • Thermo Scientific鈩? class= GasWorks software
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/oretronic-iv-tramp-metal-detector/ Tue, 03 Jan 2023 07:33:34 +0000 //gd-1.com/?post_type=product&p=7087 Ramsey Oretronic Tramp Metal Detector Features:

    • Simple installation 鈥?no belt cutting, special tools or instruments.
    • Microprocessor-based control unit automates system set-up and calibration.
    • Operator interface provides easy-to-read indicators and simplified setup and system maintenance.
    • Variable frequency eliminates interference from other electrical equipment.
    • Quick Balance electronically balances the coil with the push of a key.
    • Impact-and moisture-resistant PVC coils are mounted on a fiberglass support structure.
    • Offset Swing Arm protects the coils and reduces breakage.
    • Single coil (optional): A single, under-the-belt coil assembly eliminates damage from high burden depths and interference from overhead metal objects.
    • Distance indication (optional): When incorporating a speed sensor, the tramp metal detector鈥檚 display shows the distance from the coil to the tramp metal in tenths of feet.
    • Serial communications (optional): Plug in RS-485 communications board.

    Additional Features for the Oretronic IV 4 Control:

    • Improved sensitivity.
    • NEMA-4X enclosure.
    • External reset button.
    • Optional RS-485 communication card.
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/ramsey-series-14-belt-scale-system/ Tue, 03 Jan 2023 07:25:38 +0000 //gd-1.com/?post_type=product&p=7083
  • Full-floating unitized assemblies with no pivots or moving parts, for assured longevity with minimal measurement errors and maintenance.
  • Factory pre-assembled rigid structural steel tubing construction, for fast and easy installation.
  • Warranted weighing and totalizing performance and repeatability, for the most demanding basis-of-payment applications.
  • Durable, high-performance speed-sensing device, for exemplary accuracy and reliability over the long term.
  • State-of-the-art microprocessor-based electronics with 7鈥?HMI touchscreen display, for simple, effective operation.
  • Web based interface, for monitoring and management from a network PC
  • Extensive communications capabilities, for streamlined integration with existing control platforms.
  • Intuitive to use and calibrate with on-board system diagnostics, for optimal performance with minimal manual input.
  • ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/ramsey-series-20-belt-scale-system/ Tue, 03 Jan 2023 07:08:58 +0000 //gd-1.com/?post_type=product&p=7079
  • Easy to install, indoors or out, on fixed or portable conveyors
  • Time-proven design for challenging applications
  • State of the art microprocessor-based electronics with 7鈥?HMI touchscreen display
  • Web based interface to manage integrator from network PC
  • Improved communication capabilities
  • Intuitive to use and calibrate, with on-board system diagnostics
  • ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/thermo-scientific-ramseytm-series-17-belt-scale-systems/ Tue, 03 Jan 2023 07:01:24 +0000 //gd-1.com/?post_type=product&p=7075
    Run your high-speed plant and process operations with better-than-normal accuracy of 卤0.25% using the Thermo Scientific鈩?Ramsey鈩?Series 17 Belt Scale System. The longer weighbridge permits more scale-borne time, which minimizes alignment errors and translates into better accuracy. This belt scale system is available in a two-or four-idler version. The system provides vital information that allows you to effectively manage and efficiently operate your business by monitoring production input, output and inventory or regulating product loadout.
    ]]>
    The Ramsey Series 17 Belt Scale System features:

    • Long weighbridge design offers high accuracy of up to 卤0.25%
    • Long weighbridge permits more scale-borne time, minimizing alignment errors
    • Belt scale system available in a two or four-idler version for greater accuracy
    • Time-proven design for challenging applications
    • State of the art microprocessor-based electronics with 7鈥?HMI touchscreen display
    • Web based interface to manage integrator from network PC
    • Improved communication capabilities
    • Intuitive to use and calibrate, with on-board system diagnostics
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/micro-tech-9101-thermo-scientific-ramsey/ Tue, 03 Jan 2023 06:47:26 +0000 //gd-1.com/?post_type=product&p=7071
  • State of the art LCD graphic display with four line display
  • Self-diagnostics, alpha numeric alarm messages
  • Built-in USB for information upload and download
  • Multiple language interface
  • Improved communication capabilities
  • Audit trail
  • Automatic zero and span calibration
  • Auto zero tracking
  • Alarms and failure detection
  • Available in panel and field mount versions
  • ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/cqm-flex-coal-analyzer/ Mon, 24 Oct 2022 05:45:49 +0000 //gd-1.com/?post_type=product&p=6763 252Cf) as its source of neutrons to meet the needs of various application requirements. The CQM FLEX measures and reports levels of sulfur, moisture, total ash, calorific value, ash elemental concentration, and other critical parameters required by both coal consumers and producers to maximize the use of coal resources and reduce pollutants.]]> The CQM FLEX is a second generation analyzer developed from the original, highly successful and accurate CQM. This full-featured analyzer offers many advantages:

    • Neutron sourcing from traditional 252Cf radioactive source, or by an electrically driven neutron generator which can be used to measure elements such as carbon, hydrogen and oxygen in addition to ash constituents. The analyzer can be configured to switch between these neutron sources during the lifetime of the analyzer.
    • Fixed geometry analysis zone, designed to provide best performance and repeatability while negating adverse effects such as loading variations, belt tracking, belt composition etc. normally associated with over belt type analyzers.
    • Real time, online analysis using prompt gamma neutron activation analysis (PGNAA) technology to proactively address process variations and ensure more consistent coal blends and improved fuel quality
    • Direct measurement of calorific value by analysis of carbon, sulfur, hydrogen and oxygen concentrations
    • Reduction in CO2 emissions due to improved boiler efficiencies
    • Addresses coal quality issues in applications including load outs, truck and rail receipted coal using auger samplers, and specifically at power plants for 鈥渁s received鈥?and 鈥渁s fired鈥?coal applications.
    • Comprehensive, easy-to-use operator interface provides extensive data analysis capabilities.
    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/eca-3-elemental-crossbelt-analyzer/ Mon, 24 Oct 2022 05:23:47 +0000 //gd-1.com/?post_type=product&p=6758 Coal mines must meet a variety of customer specifications for different coal qualities.The Thermo Scientific鈩? class= ECA-3 Elemental Crossbelt Analyzer provides real-time quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control. Productivity is improved in pit management, preparation plants and inventory management.The ECA-3 Analyzer is ideal for raw coal, plant feed, clean coal and blended coal applications. Coal fired power plants benefit by reducing the use of higher, more expensive quality coals while increasing boiler efficiency.

     

    ]]>
    Online analyzer – C么ng ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/particle-tracking-analyzer-nano-zetaviewx30/ Thu, 25 Aug 2022 16:18:40 +0000 //gd-1.com/?post_type=product&p=6133 ZetaView 庐 is a nanoparticle tracking analyzer (NTA) for hydrodynamic particle size measurement, zeta potential, concentration and fluorescence. With the combination of next-generation laser precision for perfect illumination of the NTA channels and very short conversion times and intelligent software - prerequisites for dot quantification of biomarkers.]]>
  • Size:聽 (W x D x H): 20 x 30 x 25cm
  • Weight: 8.5kg (main unit, PC and secondary monitor)
  • Standard shipping box:
  • Main machine: 51 x 32 x 77cm; 16.9 kg to 18.5 kg *

    Minimum screen 24”: 61 x 18 x 48cm; 7.42 kg

    • Power supply: 90-240V, 47-63Hz, 50VA

    FEARTURES

    1. NTA Scan: automatic measurement performed at 11 locations via the sampling cell, providing thorough and robust sample testing with no need for additional accessories
    2. Fixed assembly design: Significantly improved performance and fewer errors
    3. Auto-align and auto-focus: Auto-optimized software design saves users preparation time and eliminates subjective errors from users
    4. Fast measurements: Analyze over 2000 particles in 60 seconds
    5. Quick and simple cleaning: Cleaning between samples requires only a quick flush, new fixed cell design allows very quick access to the measuring cell with bayonet lock
    6. Intuitive software: The light system immediately shows whether the sample is at the right concentration for measurement and shows the dilution factor of the sample
    7. Compact all-in-one: Measure size, concentration, Zeta potential and fluorescence with one instrument. Compatible with data files and lab environments
    8. Fluorescence analysis: Fluorescence NTA measurements allow the examination of sub-particles in the sample. Sensitive CMOS camera, up to 11 filters and low bleaching efficiency for high fluorescence sensitivity
    9. No high-cost consumables: Only syringes and reference standards required for scattering and fluorescence measurements
    10. No calibration required: Dimensional measurements do not need to be calibrated as the method is absolute

    MAIN APPLICATION

    1. Biological nanoparticles: extracellular vesicles (EVs); exosomes; Liposomes & micelles; Synthetic proteins; Viruses and new generation vaccines -virus envelope vaccines (VLP); Transportation of drugs; fluorescently labeled nanoparticles (NPs)
    2. Low concentration samples: Nanobubbles, nanometers, quantum dots, tracking particles
    ]]>