Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com Mon, 16 Sep 2024 09:46:58 +0000 en-US hourly 1 //wordpress.org/?v=6.6.2 //gd-1.com/wp-content/uploads/2021/02/favicon-32x32.png Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com 32 32 Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/biolector-xt-microbioreactor/ Mon, 16 Sep 2024 09:46:58 +0000 //gd-1.com/?post_type=product&p=13441

Innovative New Gassing Head

  • Enables fed-batch experiments under anaerobic conditions
  • Gassing with O2 within a range of 1% – 100% and with CO2 within 1% – 12 %
  • Reduces gas consumption to a few mL/minute
  • Optional humidification of gases reduces evaporation

Optional Microfluidic Module

  • Unleashes full potential of the BioLector XT
  • Complements online monitoring function with well-specific pH regulation/feeding
  • Enables use of 2 reservoir wells per 4 cultivation wells
  • Microvalves allot liquids at nanoliter-scale

“Plug-and-play�Plate Design

  • Real-time kinetics out of 48/32 parallel cultivations
  • Customizable feeding strategies (batch, fed-batch, bolus, continuous)*
  • Control of pH on-the-plate with pre-calibrated optical sensors*
  • Small working volume (800 â€?2400 μL)

*Functionality requires optional microfluidic module

Intelligent BioLection Software

  • Intuitive user interface supports multi-user environments
  • Free programming of all control parameters
  • Open system enables live data downloads
  • Fast processor ensures rapid download of experiment data
]]>
Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/cytoflex-nano-flow-cytometer/ Mon, 15 Apr 2024 03:57:52 +0000 //gd-1.com/?post_type=product&p=12225 sensitive, consistent and flexible solution that can help them advance their research. The CytoFLEX nano Flow Cytometer is a pivotal development in flow cytometry that allows users to analyze extracellular vesicles (EVs) at least as small as 40 nm* with ease while simultaneously offering up to 6 separate fluorescent channels of detection and 5 side scatter channels, to deliver full characterization and open additional avenues for your nanoparticle research.]]> Explore the full picture of your EV experiment with the CytoFLEX nano Flow Cytometer. This purpose-built flow cytometer provides greater sensitivity, consistent instrument performance, and flexibility to study your sample.

Sensitivity

With an unparalleled size sensitivity from 1µm to 40nm* and 10nm resolution,** the CytoFLEX nano flow cytometer enables the detection of smaller EV populations and their low-abundance cargo.

Flexibility

Open up your research with 6 fluorescent channels and 5 side scatter channels. Gather all the necessary data with fewer constraints.

Maximum Consistency

Maintaining contamination-free, robust instrument performance is critical when working with small size particles. Obtain reproducible results you can trust with >90% volumetric counting accuracy and <1% carryover between samples thanks to automated QC controls.

Familiarity

Built on the same principles as the CytoFLEX platform, the CytoFLEX nano flow cytometer features a similar footprint and user-friendly software interface.

The CytoFLEX nano analyzer utilizes  CytExpert for CytoFLEX Acquisition and Analysis Software and has the ability to count, size, and characterize EVs using a single technique, propelling your research forward.

Size Count  Characterize
Particle size determination by flow cytometry requires calibration using an appropriately characterized reference particle paired with a calibration method. Latex polystyrene particles are the tool of choice for this task due to their NIST-traceable nature and reliably consistent manufacturing. Through the calibration method taught to each CytoFLEX nano flow cytometer customer, data will be reliably reportable in absolute units for method comparison and correlation. The most robust counting methods rely on highly controlled volumetric delivery of samples rather than hand loading samples with the implied variability. The CytoFLEX nano flow cytometer allows users to customize their sample handling so that the right amount of sample is used for the results needed. The ability to describe nanoscale particles requires best-in-class sensitivity. To make this possible, the CytoFLEX nano flow cytometer has completely redesigned the optics and fluidics system to maximize the detection of even the smallest amounts of fluorescence across 6 detection channels and excited by 4 collinear lasers.
]]>
Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/multisizer-4e-coulter-counter/ Thu, 14 Mar 2024 07:59:37 +0000 //gd-1.com/?post_type=product&p=11724
  • Mammalian cells
  • Bacteria
  • Yeast
  • Abrasives
  • Toner particles
  • Cell aggregates
  • Spheroids
  • Large protein aggregates
  • ]]>

    Versatility

    • Aperture sizes from 10 µm – 2000 µm in diameter for current & future needs
    • Multiple aperture options & data overlay capability for analyzing complex samples over wide particle size distribution

    Sample Detection

    • Analyze materials in aqueous or non-aqueous solvents
    • Ideal for biological or non-biological samples
    • Detect particles regardless of material type or optical properties

    Rapid Particle Counting

    • Typical sampling rates up to 10,000 counts per second
    • Detect & count particles from 0.2 µm – 1600 µm in diameter
    • Sample volumes as small as 5 mL

    Data Management

    • Digital pulse data can be stored & re-analyzed as needed
    • CFR 21 Part 11 compliant software for audit control & security
    • Variety of calibration beads & V-check validation controls
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/ls-13-320-xr-particle-size-analyzer/ Thu, 14 Mar 2024 07:55:35 +0000 //gd-1.com/?post_type=product&p=11723 PIDS technology,* which enables high-resolution measurements and an expanded dynamic range. Like the LS 13 320, the XR particle size analyzer provides fast, accurate results, and helps you streamline workflows to optimize efficiency. Some big improvements help you reliably spot small differences that can have a huge impact on your particle analysis data.
    • Direct measurement range from 10 nm â€?3,500 µm
    • Automatically highlights pass/fail results for faster quality control
    • Enhanced software that simplifies method creation for standardized measurements
    • New control standards to adequately verify instrument/module performance
    ]]>

    Spot Small Differences

    • Expanded measurement range: 10 nm â€?3,500 µm
    • Laser diffraction plus advanced Polarization Intensity Differential Scattering (PIDS) technology enable high-resolution measurement & reporting of real data down to 10 nm
    • Provides accurate, reliable detection of multiple particle sizes in a single sample

    Easy-To-Use Software

    • ADAPT Software features automatic pass/fail check
    • Pre-configured methods deliver results with 3 clicks or less
    • Simplifies analyzer operation by experts & novice users alike
    • 1-click overlay with historical data
    • Intuitive user diagnostics keep you informed during sampling
    • Simplified method creation for standardized measurements

    ADAPT Software enables 21 CFR Part 11

    • Customizable security system to meet diverse needs
    • Choose from 4 security levels
    • High-security configuration supports 21 CFR Part 11

    PIDS Technology* for Direct Detection of 10 nm Particles

    • 3 light wavelengths (450, 600, & 900 nm) irradiate samples with vertical & horizontal polarized light
    • Analyzer measures scattered light from samples over a range of angles
    • Differences between horizontally & vertically radiated light for each wavelength yield high-resolution particle size distribution data
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/met-one-6015-may-dem-tieu-phan-khong-khi-tu-xa-2/ Thu, 22 Feb 2024 03:42:39 +0000 //gd-1.com/?post_type=product&p=11514 Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/met-one-6003-remote-side-exhaust-serial-interface-flow-meter/ Thu, 22 Feb 2024 03:37:43 +0000 //gd-1.com/?post_type=product&p=11509 Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/moflo-astrios-cell-sorter/ Wed, 26 Jul 2023 07:20:47 +0000 //gd-1.com/?post_type=product&p=9209
  • Available with up to 7 spatially separated lasers and 51 parameters
  • Six-way jet-in-air proficiency
  • Dual forward scatter (EQ) and single forward scatter (EQs) models
  • Features [patent] enhanced Forward Scatter (eFSC) technology
  • ]]>
    Simplify your most complex sorting tasks with the Astrios EQ Series of high-speed flow cytometry sorters. The Astrios EQ and EQs deliver powerful sorting capability while reducing complexity.

    • Available with up to 7 spatially separated lasers and 51 parameters
    • Six-way jet-in-air proficiency
    • Dual forward scatter (EQ) and single forward scatter (EQs) models
    • Features [patent] enhanced Forward Scatter (eFSC) technology

    Optics

    • 7 laser / 7 pinhole configurable system; 355 nm, 405 nm, 488 nm, 532 nm, 560 nm, 592 nm, 645 nm.
    • Single Multi-Laser Shaping Optic (MLSO) for fiber-coupled lasers
    • Flat-Top beam profile on fiber coupled lasers increases beam stability and alignment ease
    • 7 lasers aligned through two alignment stages for quick sorter set up

    Performance

    • IntelliSort II: Beadless drop delay determination and monitoring
    • 6-way sorting with a variety of collection devices (temperature control for all sort outputs available with water bath option)
    • Reproducibly sort up to 1536-well plates (due to historically 
stable fluidics)
    • Only sorter capable of 70,000 sort decisions/second validated 
performance

    Electronics and Software

    • Electronic capability to simultaneously detect 44 parameters
    • > 100,000 events/second acquisition rate validated performance
    • 1 billion events .fcs files with no parameter limit
    • Up to 2 FSC channels including user-selectable FSC masks
    • Optional additional SSC detection off each wavelength greater than or equal to 405 nm

    Biosafety

    • Custom Baker SterilGARD BSL2 cabinet
    • Single turnkey aerosol evacuation direct from sorter sort chamber to HEPA enclosure
    • Quick release nozzle design for easy access to nozzle tip
    • CyClone plate arm with wiper seals back of sort chamber
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/cytoflex-srt-benchtop-cell-sorter/ Wed, 26 Jul 2023 07:16:39 +0000 //gd-1.com/?post_type=product&p=9205
  • Capable of complex sort logic, including 4-way sorting, Mixed Mode sorting, and the ability to catch aborts and preserve precious cells
  • Setup is smart and simplified, using automation to establish and maintain the sort stream
  • Remote support ready using BeckmanConnect for on demand access to our technical specialists, perform many routine maintenance procedures independently
  • ]]>

    CytoFLEX that Sorts

    • Exquisite sensitivity for multicolor applications
    • Parameter matched to the CytoFLEX S V-B-Y-R Series
    • Intuitive software to facilitate multicolor analysis, CytExpert for CytoFLEX SRT

    Accessible Sorting

    • From startup to sample sorting in <30 minutes
    • Uses technology to increase ease of use by automating sort stream setup and maintenance throughout the sort
    • Designed for reliability and supported by teams of experts

    Complex Sort Logic

    • Up to 15 fluorescent colors to define populations
    • 4-way sorting, Mixed Mode sorting
    • Ability to catch aborts and preserve precious cells

    Delivering Quality Cells

    • High recovery and post sort viability
    • Accurate single-cell deposition using the Cyclone Movement System, including Index Sorting
    • Sort into tubes, slides, or microplates
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/cytoflex-flow-cytometer/ Wed, 26 Jul 2023 07:13:17 +0000 //gd-1.com/?post_type=product&p=9201
  • Violet-Blue-Red (V-B-R) Series, fully activated with 13 colors or as few as four, activate additional channels in the future
  • Includes 13 band pass filters: 450/45, 525/40 (2), 585/42, 610/20 (2), 660/10 (2), 690/50, 712/25, 780/60 (3)
  • For higher throughput applications an optional plate loader module is available and for use in regulated environments the software contains tools for 21 CFR Part 11 compliance
  • ]]>

    Exquisite Sensitivity

    • Unique collection of innovative technologies provide exceptional detection capabilities
    • Large dynamic range to resolve dim and bright populations in the same sample
    • Use violet side scatter to detect nanoparticles

    Platform Versatility

    • Purchase the number of parameters needed now
    • Add more detection channels by purchasing an activation key
    • Includes full complement of repositionable bandpass filters, non-standard filters also available for even more flexibility

    Low Maintenance

    • Lasers, steering optics and flow cell are all mounted onto a vibration isolated table, maintaining optical alignment
    • Low pressure fluidics system
    • Preventive Maintenance can be completed by the user, no service visit required

    Automation Enabled

    • Optional 96-well plate sample loader module
    • API (Application Programming Interface) allows external software to control the instrument
    • For automated sample processing and data acquisition integrate with the Biomek i-Series Instrument
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/dxflex-flow-cytometer/ Wed, 26 Jul 2023 07:00:49 +0000 //gd-1.com/?post_type=product&p=9197
  •  Wavelength Division Multiplexing (WDM) detection modules offer superior signal resolution
  • Simplified system settings, data acquisition & result export functions
  • Different instrument configurations available with up to 3-laser and 13-color detection
  • Optional DxFLEX Autoloader decreases the hands on time with multiple tube loading and plate loading*
  • Compact design for use in biological safety cabinets
  • ]]>
    A compact design, intuitive software, up to 13-color detection and an enhanced optical path for increased sensitivity ensure accurate results and makes flow cytometry data collection easy even for novice users.

    Flow System

    • Inlet system for 12×75 mm & micro-scale sample tube loading via single tube loader(up to 30,000 events per sec)
    • DxFLEX Autoloader is compatible with 32-tube carousel and 96-well plates*
    • Preset cleaning & maintenance programs with automatic maintenance reminders for easy maintenance
    • Three preset sample rates (high; medium; low) plus user-controlled option

    * Plate loading is not available as CE-IVD

    Intelligent Software

    • Simple intuitive interface & automated parameter optimization for improved work efficiency
    • Graphical operating tools for adjusting threshold, gain, compensation & more directly on results graph
    • Convenient compensation library stores compensation values of fluorescent dyes in multicolor experiments for future use
    • English/ Chinese bilingual interface

    Standardized QC

    • Automated instrument quality control procedures & reporting (laser delay/power, channel gain, mean fluorescence intensity, rCV) for more reliable stable results
    • Standardization procedure can be used to monitor Median Fluorescent Intensity (MFI) and track gain changes for assays.
      Optical System
    • The DxFLEX flow cytometer uses Avalanche Photodiode detectors instead of PMTs. The low electronic noise contributes to the resolution capabilities of the instrument.
    • Wavelength Division Multiplexer uses bandpass filters to deconstruct the light and efficiently deliver to the detectors by fiber optics.
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/optima-xe-ultracentrifuge/ Thu, 29 Jun 2023 03:51:49 +0000 //gd-1.com/?post_type=product&p=8668 TM XE simplifies use while offering secure loading for efficient, worry-free separations. Designed as a total system, Optima instruments, rotors and labware are designed, manufactured and tested as an integrated system for optimal performance and safety. The Optima XE features:
    • Intelligent user interface
    • Multi-layered biosafety features
    • Efficient energy use
    ]]>
    Energy Efficient Technology 

    • Maintains runs during power fluctuations
    • Run Recovery feature allows to continue a run once the power is restored
    • Regenerative braking and low idle power equates to lower power consumption from the centrifuge

    Easy to Use Interface 

    • 38.1cm (15â€? LCD touchscreen display
    • Allows for large icons for easy selection
    • Status can be seen from across lab
    • Touchscreen works with many glove types
    • 9 different languages available for the intuitive interface (most in industry)

    Enhanced Safety

    • Rotor overspeed disc
    • Dynamic Rotor Inertia Check (DRIC)
    • BioSafe optional dual PALL® Pharmaceutical-Grade Sterilizing Filters

    Quiet Drive Technology

    • Designed for the lowest drive noise, which equates to less than 51 dBA during operation.
    ]]>
    Beckman Coulter – Công ty TNHH TM DV KT Minh Khang //gd-1.com/en/san-pham/met-one-r4800-and-r4900-remote-air-particle-counters/ Mon, 26 Jun 2023 03:48:10 +0000 //gd-1.com/?post_type=product&p=8602

    Easy Integration

    • MET ONE R4800 series remote air particle counters use standard RS-485 serial communications
    • MET ONE R4900 series remote air particle counters use industry standard 4-20mA interface
    • Stainless steel enclosure compatible with most process environments
    • Compact size for easy mounting with a vacuum source, DC power & communication line

    Data Management

    • MET ONE R4800 & R4900 counters respond to simple ASCII command instructions, including start, stop and report counts, send location number, etc.
    • Reporting data includes counter status & particle counts in two size ranges
    • Multiple display options via continuous monitoring feature (Particle Vision® Online & CIMScan® software

    Operation

    • User-programmed alarm level detects high counts on first channel triggering an alarm
    • Auto alarm reset at start of the next count cycle
    • Long-life laser technology for superior performance & extended service life
    • No fan allows proximate placement to sensitive processing areas

    Flexible

    • Sensitivity ranges of 0.5um & flow rates of 1.0 cfm
    • Onboard status indicator sets signal at connector for alarm Stay resident RS-485 configuration programming (count/hold times, alarm level/delay & scaling) maintained through power cycles
    • Sensor resistant to  vaporous hydrogen peroxide (VHP)
    ]]>