Chemistry |
Oxidation by combustion: From 680 °C – 1000 °C |
TOC probe |
Non-dispersive infrared absorption (NIDR) sensor with static pressure (SPC) – patented |
Analysis mode |
TOC (NPOC), TC-IC, TC, IC |
TOC analysis |
Detection limit: 50 ppb
Measurable maximum concentration: 30,000 ppm
Backlog: 1.0% cross-contamination
Sample Size: 100 L to 2.0 mL
Accuracy: 1.5% RSD, ±15 ppb |
Analysis time |
6 – 10 minutes. 29 minutes for 3-sample TOC analysis |
Carrier gas treatment |
Mass flow controller for instant control of carrier gas (0-500 mL/min). Automatic leak testing capabilities |
Liquid handling |
Cylinder driver, 7-port distribution valve. Auto-dilution capability for higher TOC concentrations and difficult substrates.
The self-cleaning sample handling process cleans the injection line after each iteration. |
Sample Loading |
Built-in autosampler |
Remote controll |
PC, Interface via Windows™ 7 or later |
Data processing |
Reports can be exported to XML, CSV and HTML formats
Real-time and historical graphical display of NDIR & CLD . probe data
Ability to import from CSV files and view historical results from multiple schedules on a single graphical display.
Possibility to store custom individual test methods
Priority patterns via schedule interrupt
Recalculate data, remove deviations, and control precise performance criteria (21 CFR Part 11 Compliant – Electronic Signatures and Audit Trails) |
Calibration |
Automatic calibration from single origin standards or user calibration standards |
21 CFR Part 11 Software Compliant |
TOC TeklinkTM software is a 21 CFR Part 11 compliant tool for your lab |
Other features |
– Pre-programmed pointing and clicking method setting
– Automatic sample/standard dilution
– Device status/mode light
– ASM Sparge . method
– Authentication support package available
– Stir option
– Auto off/standby
– Dilution |
Main application |
Wastewater, Industrial Wastewater, Drinking and Surface Water, Groundwater, Clean-in-Place (CIP) Valid, Sea Water |
Method |
EPA 415.1, 415.3 and 9060A, Standard Method 5310B, EP 2.2.44, ISO 8245, EN 1484, USP 643 (Chapter 24), ASTM D2579, prENV 13370, AOAC 973.47 |
Certifications |
CE, EMC EN 50081-1 and EN 50082-1 |
Requirements |
Voltage: 100/120/240 VAC (± 10%) factory configured, Frequency: 50/60 Hz, Power: 1200VA |
size |
18” W x 24.5” D x 32” H, Shipping Weight 147 lbs |
Gas supply |
Free Air Hydrocarbon and Carbon Dioxide (CO2) (with oxygen greater than 18%) with TOC <1ppm or UHP O2. Gas can be supplied from a cylinder or a TOC generator. If a TOC generator is used, the gas formed must be hydrocarbons and not contain water. To ensure the use of clean carrier gas, we recommend using a complete CO2 removal system and trapping hydrocarbons between the gas source and the analyzer. |
Inlet gas pressure |
65 to 100 psi |
Autosampler |
– Accuracy: ±2.5 mm
– Reproducibility: ± 0.25 mm
– Force from the vertical stamping unit: 8.3 lbs
– Automatic wash from sample and/or wash water via integrated wash station |